ATEX:
II 2 G IIC T4 or T3 Gb
NEC 500: Class I, Div. 2, Groups B, C, D, T4 or T3
NEC 505: Class I, Zone 1, AEx IIB+H2 T4 or T3
CEC Sec. 18: Class I, Zone 1, Ex IIB+H2 T4 or T3
TR CU Certification available
ASTM D2270
ASTM D341
operation +5 up to +40 °C (+41 up to +104 °F)
All fluids that fulfil the conditions of Newton’s friction law are referred to as Newtonian fluids. Their viscosity is a material constant, which is only dependent on pressure and temperature. The viscosity index is a widely used and accepted measure of the variation in kinematic viscosity due to changes in the temperature of a petroleum product between 40 and 100°C. A higher viscosity index indicates a smaller decrease in kinematic viscosity with increasing temperature of the product.
The BARTEC BENKE Viscosity Index Process Analyzer VI-4 consists of two viscosity process analyzer units. One analyzer unit measures the kinematic viscosity at a temperature of 40°C and the other at a temperature of typically 100°C. These two values are used to calculate the VI according to ASTM D2270. Due to the outstanding performance and sample temperature stability of ± 0.02 K the VI-4 is the best choice for highly accurate viscosity index measurements e.g. lube oil production and fuel oil blending. This high level of accuracy results in cost reduction while improving product quality. The VI-4 is suitable to handle samples with a viscosity of up to 800 cSt at measurement temperatures of up to 100°C.
Data Sheet - Viscosity Index Process Analyzer VI-4